OVERVIEW
• 24 field configurable input ranges
• DC Voltage Input: 0-50 mV to +/- 10 V
• DC Current Input: 0-1 mA to 0-20 mA
• Output: (1) DPDT Relay
• Field-Configurable by User
Options:
TECHNICAL SPECIFICATIONS
Input
Field Configurable
Voltage: 0-50 mVDC to +/- 10 VDC
or
Current: 0-1 mADC to 0-20 mADC
Output
One DPDT 7A contact set
Field adjustable setpoint; HI/LO, Latch/No Latch, Normal/Reverse Action
Features
Minuteman one-minute setup
Hot-swappable plug-in design
LoopTracker LED
Alarm status LED
Output test/alarm reset button
18 V loop power supply
Uses API-011 11-pin socket
115 VAC powered
D option for 9-30 VDC power
Applications
Process Limit Backup Alarm
Tank Level Alarm
Over, Under, Out-of-Range Alarm
DOCUMENTS & DOWNLOADS
VIDEOS
No Result Found
PRODUCT NUMBERS
Field Configurable Alarm Module for Process Monitoring and Control
The API 1080G DC Input Alarm Trip is a field-configurable signal monitoring module designed to provide reliable, real-time alarm indication and relay output when a process signal exceeds or falls below a defined threshold. Built for industrial automation and process control applications, the 1080G accepts a wide range of DC voltage or current inputs and activates a heavy-duty relay output based on a user-defined setpoint.
With flexible input selection, adjustable setpoint and deadband, and a robust DPDT relay output, the API 1080G provides a dependable solution for safeguarding equipment, improving process visibility, and ensuring safe operation.
Monitor Critical Process Signals with Confidence
The API 1080G continuously monitors an analog DC signal and triggers an alarm condition when the input crosses a defined setpoint. This enables operators to quickly identify and respond to abnormal conditions such as over-range, under-range, or out-of-tolerance signals.
Typical monitored signals include:
4–20 mA process signals
0–10 VDC control signals
Low-level millivolt signals
Sensor outputs from pressure, temperature, or level transmitters
This makes the 1080G ideal for use in process control systems where reliable alarm indication is critical.
Wide Range of Field-Selectable Inputs
The API 1080G supports a broad range of input signals, allowing it to be used with virtually any industrial sensor or transmitter.
Voltage inputs: 0–50 mV up to ±10 VDC
Current inputs: 0–1 mA up to 0–20 mA
Field-selectable input ranges are configured using external switches, enabling quick adaptation to different applications without requiring specialized tools.
Single Setpoint Alarm with Flexible Configuration
The API 1080G provides a single alarm setpoint that can be configured for multiple operating modes.
Alarm Configuration Options:
High (HI) alarm or Low (LO) alarm
Latching or non-latching operation
Normal acting or reverse acting relay behavior
This flexibility allows the module to be tailored to a wide range of monitoring requirements, from simple limit alarms to more advanced safety interlocks.
Adjustable Setpoint and Deadband
The API 1080G allows precise control over when the alarm is triggered and reset.
Setpoint adjustment: 0 to 100% of input span
Deadband adjustment: 1% to 100% of span
The deadband feature helps prevent relay chatter in applications where the input signal fluctuates near the setpoint. By adjusting the deadband, users can create a stable operating window that minimizes false alarms.
Heavy-Duty DPDT Relay Output
The module features a robust double-pole, double-throw (DPDT) relay output capable of handling a wide range of loads.
7 A @ 240 VAC (resistive load)
3.5 A @ 240 VAC (inductive load)
8 A @ 30 VDC maximum
This allows the API 1080G to directly control:
Alarms and warning systems
Pumps and motors
Valves and actuators
Safety shutdown systems
The relay output provides both normally open (NO) and normally closed (NC) contacts for flexible system integration.
Built-In Loop Power Supply
The API 1080G includes an integrated loop power supply that can be used to power external loop-powered transmitters.
18 VDC nominal output
Up to 25 mA capacity
This eliminates the need for an external power supply, simplifying wiring and reducing system complexity.
LoopTracker® and Alarm Status LEDs
The API 1080G includes visual indicators that provide real-time feedback on system status.
LoopTracker LED:
Indicates input signal level
Brightness varies with signal strength
Helps identify wiring or signal issues
Bi-Color Alarm LED:
Green = normal condition
Red = alarm condition
These indicators provide immediate visual confirmation of both process conditions and alarm status.
Functional Test and Reset Capability
The module includes a front-accessible test/reset push button that allows operators to verify system operation without altering the input signal.
Toggles relay output independently of input
Verifies alarm and system functionality
Resets latching alarms
This feature simplifies commissioning and troubleshooting.
Fast Response Time for Real-Time Protection
The API 1080G is designed to respond quickly to changing process conditions:
Typical response time: 70 milliseconds
This ensures timely detection of critical events and rapid activation of alarm outputs.
Rugged Industrial Design
The API 1080G is built for reliable operation in demanding environments:
Operating temperature: –10°C to +60°C
Compact plug-in design
DIN rail or panel mounting using standard 11-pin socket
Conformal coating option available for moisture resistance
Its durable construction ensures long-term performance in industrial applications.
Typical Applications
The API 1080G is widely used in applications requiring reliable alarm monitoring:
Process limit backup alarms
Tank level monitoring
Over-range and under-range detection
Equipment protection systems
Industrial automation and control
It is especially useful in systems where immediate notification of abnormal conditions is required.
Why Use a Setpoint Alarm Module?
Setpoint alarm modules provide a critical layer of protection in industrial systems by:
Monitoring process variables continuously
Providing immediate feedback when limits are exceeded
Triggering automated responses or shutdowns
Improving safety and system reliability
The API 1080G delivers these capabilities in a compact, easy-to-configure package.
Why Choose the API 1080G?
The API 1080G stands out as a reliable and flexible alarm solution due to its:
Wide range of field-selectable input signals
Configurable alarm modes (HI/LO, latching, reverse acting)
Adjustable setpoint and deadband
Heavy-duty DPDT relay output
Built-in loop power supply
Visual status indicators for easy monitoring
Fast response time
Rugged industrial design
A Reliable Solution for Process Alarm Monitoring
The API 1080G DC Input Alarm Trip provides a dependable way to monitor critical process signals and trigger alarms when necessary. Its combination of flexibility, performance, and ease of use makes it an essential component in industrial control systems.
Enhance Your Process Safety and Control
Whether you are protecting equipment, monitoring process limits, or improving system visibility, the API 1080G delivers the performance and reliability needed to ensure safe and efficient operation.
Contact us today to learn more or configure a solution tailored to your application.