OVERVIEW
• Digital Pressure Transmitter with CAN J1939 Interface
• Type 0631: CAN J1 939 protocol according to SAE J1 939
• Device profile according to CiA DS-404
• Robust stainless steel construction with high reliability,even in very rough environments
• Completely welded measuring cell made of stainless steel 1.4542 ensures excellent media compatibility
• Measuring ranges from 0 -1 bar to 0 -600 bar (0 -15 psi to 0 - 8,700 psi)
The 0631 series is a robust, reliable pressure transmitter that is designed to withstand extreme operating conditions.
HGSI is a factory authorized distributor of Suco Technologies pressure switches.
 
TECHNICAL SPECIFICATIONS
| Type: | 0631 | 
| Output protocol: | CANopen DIN EN 50325-4 1),2) | 
| Supply voltage U: | 10V- 32 VDC | 
| Idle power consumption: | <30mA | 
| CAN Interface: | acc . to DIN ISO 11898-2 CAN 2.0 A | 
| Standard pressure ranges: | • 0-40 bar (580 psi) | 
| Overpressure protection: | • 0-l00 bar (1,450 psi) | 
| Burst pressure: | • 0-150 bar (2,175psi) | 
| Mechanical life expectancy: | 10.000.000 pulsations at rise rates to 1 bar/ms at p nom | 
| Permitted pressure change rate: | ≤ 1 bar/ms | 
| Accuracy: | ±0,5 % of full scale (FS) at room temperature 4), ±0,25 % B FSL | 
| Long-term stability: | <± 0, 1 % of full scale (FS) per year | 
| Repeatability: | ±0, 1 % of full scale (FS) | 
| Temperature error: | 1,5 % of full scale (FS) | 
| Compensated temperature range: | -20 ° F ... + 185 ° F (-20 °C ... +85 °C) | 
| Temperature range ambient: | -40 ° F ... +22 1 ° F (-40°C ... +105 °C) | 
| Wetted parts material: |      • Housing: Stainless steel 1.430 1 / AISI 304 | 
| Insulation resistance: | 1 00 M Ω (SO VDC , Ri > 42 Ω) | 
| Response time 10 - 90 %: | < 1 ms | 
| Vibration resistance: | 20 g acc. to IEC 68-2-6 and IEC 68-2-36 | 
| Shock resistance: | 1000 g acc. to IEC 68-2-32 | 
| Protection class: | IP 67 (IP 00 without mating plug) | 
| Electromagnetic compatibility: | EN 61326-2-3 | 
| Weight: | 90g | 
1) Further information and the standard setting can be found in the Technical Documentation CAN open (1-6-30-6 28-058) as well as
CAN J19 39 (1-6-30-628-05 9) on our CANopen webpage.
2) The EDS (Electronic Data Sheet) of our CANopen device can
3)Static pressure. Dynamic value is 30% to 50% lower. Values refer to the hydraulic/pneumatic part of the pressure transmitter.
4) Including non-linearity, hysteresis, repeatability, zero error and full scale (FS) according to I EC 612 98-2.
5)Within the compensated temperature range.
See Order matrix on page 4 of data sheet for ordering instructions
Technical explanations for pressure transmitters: see pages 5-9 of data sheet
DOCUMENTS & DOWNLOADS
VIDEOS
No Result Found
PRODUCT NUMBERS
| 0631-10041B032 | 0631-10009B032 | 0631-10041P032 | 0631-10009P032 | ||||
| 0631-25041B032 | 0631-25009B032 | 0631-25041P032 | 0631-25009P032 | ||||
| 0631-40041B032 | 0631-40009B032 | 0631-40041P032 | 0631-40009P032 | ||||
| 0631-60041B032 | 0631-60009B032 | 0631-60041P032 | 0631-60009P032 | ||||
| 0631-10141B032 | 0631-10109B032 | 0631-10141P032 | 0631-10109P032 | ||||
| 0631-16141B032 | 0631-16109B032 | 0631-16141P032 | 0631-16109P032 | ||||
| 0631-25141B032 | 0631-25109B032 | 0631-25141P032 | 0631-25109P032 | ||||
| 0631-40141B032 | 0631-40109B032 | 0631-40141P032 | 0631-40109P032 | ||||
| 0631-60141B032 | 0631-60109B032 | 0631-60141P032 | 0631-60109P032 | ||||
| 0631-10241B032 | 0631-10209B032 | 0631-10241P032 | 0631-10209P032 | ||||
| 0631-16241B032 | 0631-16209B032 | 0631-16241P032 | 0631-16209P032 | ||||
| 0631-25241B032 | 0631-25209B032 | 0631-25241P032 | 0631-25209P032 | ||||
| 0631-40241B032 | 0631-40209B032 | 0631-40241P032 | 0631-40209P032 | ||||
| 0631-60241B032 | 0631-60209B032 | 0631-60241P032 | 0631-60209P032 | 
 
     
 
           
  
  
 